摘要
设计的主要内容是进行湖北省宜城县城关镇给水工程设计,其中设计的主要内容为:选择设计规模,给谁系统选择,取水泵房设计,净水厂设计,送水泵房设计和给水管网设计和工程概预算。毕业设计成果为设计说明计算书和设计图纸。
根据资料,本设计规模近期27万m³/d,远期41万m³/d。设计以汉江为取水水源,采用的给水系统为:水源-取水泵站-折板絮凝池-平流沉淀池-V型滤池-清水池-送水泵房-市政管网。选用PAC为混凝剂,消毒方式为液氯消毒。水厂出水水质要求达到生活饮水卫生标准。
水厂位于宜城县城关镇的西北方向,地面标高为55.00m,水厂占地面积约为5万平方米,其中绿化面积约为25%,附属建筑物面积约占总面积的25%。
关键词 宜城县城关镇 给水工程 市政管网 泵站 水厂
Abstract
The main content of the design is to design the water supply project of Chengguan Town, Yicheng County, Hubei province. The main content of the design is to choose the design scale, choose the system for who, the design of water pump house, the design of water purification plant, the design of the pump house, the design of water supply network and the project budget. The results of graduation design are designed to explain the calculation and design drawings.
According to the data, the design scale is 270 thousand m³/d, and the forward is 410 thousand m³/d. The water supply system used in the water intake of Hanjiang River was designed as water source - water pump station - folding plate flocculating pool - -V filter tank of flat current sedimentation tank - water pump room - municipal pipe network. PAC was used as coagulant and disinfection by liquid chlorine disinfection. The water quality requirements of the water treatment plant reach the hygienic standard of drinking water.
The water plant is located in the northwest direction of Chengguan Town, Yicheng county. The ground elevation is 55.00m. The water plant covers an area of about 50 thousand square meters, of which the green area is about 25%, and the area of the subsidiary buildings is about 25% of the total area.
Keywords Yicheng Chengguan town; water supply engineering; municipal pipe network ;pumping station; water plant
设计原始资料
(一) 城市概况
宜城县城关镇位于县城东部,位于襄樊市南面41km处,为襄樊市的辐射区,城关镇城区总面积9.2km²,其中建成4.1km²。
[来源:http://www.doc163.com]
目录
第一章 绪论 5
第二章 设计说明计算书 5
2.1设计原始资料 6
2.2用水量计算 7
2.3取水工程 9
2.4净水厂设计计算 17
2.5输配水系统设计计算 38
参考文献 43
结论 44
致谢 45